Type of pressure
|
Gauage type
|
Type of package
|
DIP or SMT
|
Pressure medium
|
Air or non-corrosive gas
|
|
Min
|
Nominal
|
Max
|
Unit
|
Excitation Voltage
|
--
|
5
|
10
|
V
|
Excitation Current
|
--
|
1.00
|
2.00
|
mA
|
Bridge Impedance
|
4
|
5
|
6
|
kΩ
|
Span1
|
|
|
|
|
5.8psi
|
40
|
70
|
100
|
mV
|
5.8psi*
|
75
|
100
|
125
|
mV
|
Offset
|
-30
|
0
|
+30
|
mV
|
TC Span2(Constant Voltage)
|
-0.17
|
-0.22
|
-0.27
|
%FS/℃
|
TC Span2(Constant Current)
|
-0.05
|
-0.02
|
+0.05
|
%FS/℃
|
TC Offset2
|
-0.05
|
-0.02
|
+0.05
|
%FS/℃
|
Linearity3
|
-0.3
|
±0.1
|
+0.3
|
%FS
|
Hysteresis
|
-0.3
|
±0.1
|
+0.3
|
%FS
|
Proof pressure
|
|
|
2x
|
Rated Fs
|
Burst pressure
|
|
|
3x
|
Rated Fs
|
Operating Temperature
|
-40
|
|
+125
|
℃
|
Storage Temperature
|
-55
|
|
+150
|
℃
|
1、Unless otherwise specified, span is measured at 5.0V Constant Voltage supply at 25℃.
2、Unless otherwise specified ,Temperature coefficients are Measured from 0℃ to 50℃ @ 5V Constant voltage excitation.
3、Defined as best straight line.
* 5.8 psi high sensitivity type
|